Welding fume is not one substance. It is a mixture that changes with the base metal, the filler, the process, and the coating on the part, and Cal/OSHA regulates the pieces separately. The piece that catches fabrication shops and stainless steel contractors off guard is hexavalent chromium, which has its own standard with an action level low enough that a single welder on stainless in a poorly ventilated bay can trigger monitoring, medical surveillance, and a regulated area. Most shops that weld stainless have never sampled for it.
Which Standards Apply
Three sets of Title 8 rules govern welding fume exposure.
- Section 5155 and Table AC-1 set the permissible exposure limits for the individual fume constituents: manganese, iron oxide, nickel, zinc oxide, total welding fume, and the gases welding generates. Subsection (e) requires the employer to monitor whenever it is reasonable to suspect employees may be exposed above those limits.
- Section 5206 is the hexavalent chromium standard for general industry. Section 1532.2 is the parallel standard for construction, with the same PEL and action level. Both apply to Cr(VI) in all forms and compounds, with exemptions for pesticide application, portland cement, and materials the employer can show cannot release Cr(VI) at or above 0.5 micrograms per cubic meter.
- Section 5150 for general industry and Section 1536 for construction set the ventilation and respirator rules specific to welding, brazing, and cutting. Both require local exhaust providing a minimum air velocity of 100 lineal feet per minute in the welding zone for indoor operations, and both require local exhaust in enclosed spaces when the work involves beryllium, cadmium, chromium, fluorides, lead, mercury, zinc, or inert-gas metal-arc welding or oxygen cutting of stainless steel.
Cr(VI) comes from chromium in the base metal or filler being oxidized in the arc. Stainless steel, high-chromium alloys, hardfacing rods, and chrome-containing coatings are the usual sources. Mild steel welding does not normally produce Cr(VI), but it produces manganese and iron oxide, and those have limits too.
The Numbers
These are the Table AC-1 values, 8-hour time-weighted averages unless noted, that I sample against on a welding job:
- Chromium (VI) compounds: PEL 5 micrograms per cubic meter (listed as 0.005 mg/m3), with a ceiling of 0.1 mg/m3. Section 5206 sets the action level at 2.5 micrograms per cubic meter.
- Manganese fume: PEL 0.2 mg/m3, with a short-term exposure limit of 3 mg/m3.
- Iron oxide fume: 5 mg/m3.
- Nickel metal: 0.5 mg/m3; insoluble nickel compounds: 0.1 mg/m3.
- Zinc oxide fume: 5 mg/m3, STEL 10 mg/m3.
- Welding fumes, total particulate: 5 mg/m3, with the individual constituents evaluated separately.
- Ozone: 0.1 ppm, STEL 0.3 ppm. Nitrogen dioxide: STEL 1 ppm. Carbon monoxide: 25 ppm with a 200 ppm ceiling.
The manganese number deserves attention. At 0.2 mg/m3 it is low enough that flux-cored and stick welding on mild steel without local exhaust frequently exceeds it. But the Cr(VI) action level of 2.5 micrograms per cubic meter is the number that turns a welding shop into a program shop.
What Section 5206 Requires Once You Are Above the Action Level
The standard begins with an exposure determination under subsection (d). You can use the scheduled monitoring option, meaning personal breathing-zone samples sufficient to characterize full-shift exposure for each job, or a performance-oriented option using any combination of air monitoring, historical data, or objective data. Under the scheduled option, if initial results are below the action level, you can stop. At or above the action level, you repeat at least every six months; above the PEL, at least every three months. You can discontinue when periodic results at least seven days apart show exposure below the action level. Results must be communicated to employees within 15 working days.
Once an employee’s exposure is at or above the action level for 30 or more days a year, or the employee shows signs or symptoms of Cr(VI) health effects, or there is an emergency, subsection (k) medical surveillance applies. Examinations are required within 30 days of initial assignment, annually, within 30 days of a PLHCP recommendation, within 30 days after an emergency, and at termination if the last exam was more than six months earlier. The exam covers a medical and work history focused on chromium exposure, respiratory dysfunction, asthma, dermatitis, skin ulceration, nasal septum perforation, and smoking; a physical examination of the skin and respiratory tract; and any additional tests the physician considers appropriate.
Above the PEL, subsection (e) requires a demarcated regulated area, and subsection (f) requires engineering and work practice controls to bring exposure to or below the PEL unless the employer can demonstrate they are not feasible. Respirators under subsection (g) fill the gap while controls are being installed, during maintenance where controls are not feasible, and whenever controls cannot get you below the PEL. Subsection (h) requires protective clothing where skin or eye contact is a hazard, and subsection (j) requires that Cr(VI)-contaminated surfaces be cleaned by HEPA vacuuming or other methods that minimize exposure, with dry methods allowed only where those have been tried and failed.
Training under subsection (l) has to cover the specific health effects: cancer, eye irritation, and skin sensitization. Records under subsection (m) follow Section 3204.
What an Inspector Looks For
A Cal/OSHA compliance officer who sees stainless on the bench asks three questions in order. First, has anyone measured Cr(VI) exposure? If not, the exposure determination in 5206(d) has not been done, and that is a citation before anyone picks up a sampling pump. Second, where is the local exhaust? If welders are working stainless indoors under a general shop fan, the officer will check capture at the arc against the 100 feet per minute in Section 5150(a) and note whether the hood is actually positioned where the fume is. Third, what are the welders wearing? A dust mask is not a respirator, and a half-mask with the wrong cartridge is not a Cr(VI) respirator.
The officer may sample the welders that day. If the result is above the PEL and you have no monitoring, no regulated area, no medical surveillance, and no respirator program, expect a citation for each element.
How I Run a Welding Fume Assessment
The right assessment is not a single grab sample on the worst welder. It is a full-shift personal sample on each distinct job, taken inside the welding helmet, on a representative day, with the metals analyzed separately so you know whether the driver is manganese, chromium, nickel, or total particulate. Cr(VI) requires a different sampling method and lab analysis than the metals scan, so the plan has to specify both.
The results put you in one of three positions. Below the action level on every job: document it and re-evaluate when the work changes. Between the action level and the PEL: periodic monitoring and medical surveillance, but the exposure can usually be solved with better local exhaust positioning. Above the PEL: a regulated area, engineered controls, interim respirators, and a written compliance path. Most shops I sample land in the middle on stainless, but I have seen mild-steel flux-core work come in well above the manganese PEL.
Common Gaps
- No exposure determination at all. The shop assumes the general ventilation is adequate and has no data to show it.
- Fume extractors present but parked. A fume arm two feet from the arc captures very little; the 100 feet per minute has to be at the welding zone.
- Welders on stainless wearing N95s as a habit rather than under a Section 5144 program with fit testing and medical evaluation.
- Housekeeping by compressed air or dry sweeping around stainless work, contrary to 5206(j).
- Medical surveillance never offered because nobody knew the 30-day trigger existed.
- Training that never names the Cr(VI) health effects the standard requires.
- Construction crews field-welding stainless without recognizing that Sections 1532.2 and 1536 apply on site just as 5206 and 5150 apply in the shop.
What to Do Now
- Inventory every process involving stainless, high-chromium alloy, hardfacing, or chrome-containing coating, and every flux-cored or stick process on mild steel indoors.
- Commission full-shift personal sampling for Cr(VI), manganese, nickel, and total particulate on each distinct job, inside the helmet.
- Measure capture velocity at the arc for every local exhaust unit and fix anything that does not reach 100 feet per minute where the fume is generated.
- If any result is at or above 2.5 micrograms per cubic meter of Cr(VI), calendar six-month monitoring, offer the medical examination, and document the offer.
- Replace any respirator use outside a written Section 5144 program with a proper program, or with engineering controls that make respirators unnecessary.
- Put a HEPA vacuum in the stainless area and take the compressed air blowgun out of it.
- Rewrite the welding section of your training to name the Cr(VI) health effects and your specific controls.
If you need defensible exposure data on your welding operations and a control plan that matches the results, McNeil Safety Consulting can help. Learn more about our industrial hygiene services or call (626) 546-9384.