Cal/OSHA Lead Standard 5198: The 2025 General Industry Rules

By Michael Karl McNeil, REP, RIH, EPP, QSD

California rewrote its general industry lead standard, and the changes are not cosmetic. The amended 8 CCR §5198 became operative January 1, 2025, with a permissible exposure limit of 10 micrograms per cubic meter, an action level of 2 micrograms per cubic meter, new blood lead triggers, and medical removal levels that tighten again on January 1, 2026. This post walks through what the current text says so you can measure your program against it.

Who Section 5198 Covers

Under §5198(a)(1), the standard applies to all occupational exposure to lead, except as provided in §5198(a)(2), which removes the construction industry and agricultural operations from its scope. That leaves battery work, foundries, scrap handling and any in-plant task that disturbs lead-bearing material.

The amended rule also introduces a defined category called presumed significant lead work, or PSLW, in §5198(b). It covers altering or disturbing material known to contain lead at 0.5% by weight or more (from testing or a safety data sheet), altering or disturbing material reasonably anticipated to contain that concentration such as scrap lead or lead solder, and torch cutting any scrap metal. The definition carries an exception: activity is not PSLW if the total combined exposure from those activities is under 8 hours in any 30-day period. When I review programs, PSLW is the piece most often missed, because it pulls in maintenance and scrap crews never treated as lead workers.

The New PEL, Action Level and SECAL

Section 5198(c) requires the employer to ensure that no employee is exposed to an airborne concentration of lead greater than 10 micrograms per cubic meter of air as an 8-hour time-weighted average. The action level in §5198(b) is 2 micrograms per cubic meter, also as an 8-hour TWA and measured without regard to respirator use.

For certain lead acid battery operations, §5198(e) sets a separate engineering control air limit (SECAL) in Table 1. Battery manufacturing and battery recycling operations listed in that table carry a SECAL of 50 micrograms per cubic meter beginning January 1, 2025, stepping down on January 1, 2030 to 40 or 30 micrograms per cubic meter depending on the listed process. Engineering and work practice controls must reach the SECAL; respirators cover the gap to the PEL.

Exposure Assessment and Interim Protection

Section 5198(d) requires initial monitoring wherever exposure at or above the action level is possible, using full-shift personal samples for each shift, job classification and work area. Periodic monitoring frequency then depends on the result:

  • Above 50 micrograms per cubic meter: repeat quarterly until two consecutive results taken at least 7 days apart are at or below 50.
  • From 30 to 50: repeat every 6 months until two consecutive results at least 7 days apart are below 30.
  • At or above the action level but below 30: repeat every 12 months until two consecutive results at least 7 days apart are below the action level.
  • Below the action level: no further routine monitoring, but reassess after changes in process, controls or personnel that could raise exposure.

Employees must be notified in writing of their results within 5 working days of the employer receiving them.

Until the assessment is done, §5198(d)(2) requires interim protection for employees performing PSLW: at minimum a half-mask respirator with N100, R100 or P100 filters under §5198(d)(2)(A), protective clothing under (d)(2)(B), medical surveillance under (d)(2)(C), training under (d)(2)(D), and posted signs under (d)(2)(E). You cannot wait for lab results before protecting a torch-cutting crew.

Compliance Program, Respirators and Hygiene

Section 5198(e)(2)(A) requires a written compliance program to reduce exposures to or below the PEL, or the SECAL where one applies, by engineering and work practice controls. Section 5198(e)(2)(B) lists its required contents. Under §5198(e)(2)(D), the program must be revised and updated at least every 6 months. Ventilation effectiveness must be measured at least every 3 months.

Respirator use under §5198(f) must follow the respiratory protection program in §5144. Filtering facepiece respirators must be N100, R100 or P100, and powered air-purifying respirators must use HEPA filters. Protective clothing under §5198(g) is provided at no cost and cleaned at least weekly, and daily above 30 micrograms per cubic meter.

Hygiene requirements in §5198(i) prohibit food, beverages, tobacco and cosmetics in lead exposure areas. Change rooms, showers and lunchroom facilities are required where exposure exceeds the PEL. For exposures above the PEL but not above 50 micrograms per cubic meter, the change room, shower and lunchroom provisions in §5198(i)(2)(A), (i)(3)(A) and (i)(4)(A) took effect January 1, 2026, so that phase-in has now run out.

Blood Lead Testing Triggers

Medical surveillance under §5198(j) applies to employees exposed at or above the action level and, as interim protection, to employees doing PSLW. Read the short-duration exceptions in §5198(j) carefully before excluding anyone. The blood lead schedule in §5198(j)(2)(A) is:

  1. Before assignment, or as soon as possible once the work is determined to be covered, unless the employee was tested in the preceding two months.
  2. At least every 2 months for the first 6 months, then every 6 months.
  3. The same frequency again after a work change likely to increase exposure.
  4. At least every 2 months for an employee whose last level was 10 to below 20 micrograms per deciliter, until two consecutive results at least 30 days apart are below 10.
  5. At least monthly for an employee whose last level was 20 micrograms per deciliter or higher, and during any removal period.

Under §5198(j)(2)(E)1, a blood lead level of 10 micrograms per deciliter or higher requires the employer to establish and implement a written elevated blood lead level response plan aimed at bringing the level back below 10. A level of 20 or higher also triggers zinc protoporphyrin testing and a medical examination if one has not been done in the prior 12 months.

Medical Removal Levels

Medical removal protection under §5198(k) is where the 2026 changes bite. The removal triggers in §5198(k)(1) are:

  • §5198(k)(1)(A): the last blood lead test is at or above 30 micrograms per deciliter.
  • §5198(k)(1)(B), effective January 1, 2026: the last two blood lead test results are at or above 20 micrograms per deciliter.
  • §5198(k)(1)(C), effective January 1, 2026: the average of all blood lead tests in the last 6 months is at or above 20, except that removal is not required if the last test is below 15.

Under §5198(k)(3)(A)1, a removed employee returns to former job status when two consecutive blood lead tests taken at least 30 days apart are both below 15 micrograms per deciliter. Medical removal protection benefits under §5198(k) run for up to 18 months. In the audits I conduct, the six-month average trigger is the one most often uncomputed, because nobody is assigned to track the rolling average.

Training, Signs and Records

Section 5198(l) requires initial and annual training for employees at or above the action level or doing PSLW, covering the topics listed in the section, and also requires general housekeeping and hygiene training. Warning signs under §5198(m) go in areas at or above the action level and in PSLW areas. Under §5198(n), exposure monitoring and medical records are kept at least 40 years or for the duration of employment plus 20 years, whichever is longer. Compliance program reviews, response plans and training records are kept 3 years.

How This Differs From Construction Section 1532.1

Construction work, defined as construction, alteration or repair including painting and decorating, falls under 8 CCR §1532.1, not §5198. The construction rule carries the same 10 microgram PEL and 2 microgram action level, and the same 30 and 20 microgram per deciliter removal triggers, but it is organized around trigger tasks in §1532.1(d)(2), such as manual scraping, power tool sanding, abrasive blasting and torch cutting, sorted into presumed exposure levels that dictate interim protection. It also allows abrasive blasting up to 25 micrograms per cubic meter until January 1, 2030. A contractor’s renovation crew in your plant works under §1532.1 while your own maintenance staff is likely under §5198. The construction side is covered in detail in my post on lead in construction under Section 1532.1.

What to Do This Week

  1. Compare your last air sampling results to the 2 microgram action level and 10 microgram PEL.
  2. List every task that disturbs material with 0.5% lead or more and decide whether it is PSLW.
  3. Check that your written compliance program was updated within the last 6 months.
  4. Calculate each employee’s six-month average blood lead level and flag anyone at or above 10 or 20.
  5. Confirm change rooms, showers and lunchrooms exist for any area above the PEL, now that the January 1, 2026 phase-in has passed.

If your lead program needs an exposure assessment, a rewritten compliance program, or a review of your blood lead tracking against the amended standard, see my chemical exposure assessment service, read more about industrial hygiene and medical surveillance and recordkeeping support, or request a consultation by calling (626) 546-9384.

Need help with a Cal/OSHA matter?

McNeil Safety Consulting provides Cal/OSHA citation defense, industrial hygiene, safety plan writing, and expert witness services throughout California. Call (626) 546-9384 or request a consultation.