Silica in Construction: How Table 1 Works Under 29 CFR 1926.1153

By Michael Karl McNeil, REP, RIH, EPP, QSD

Cutting a concrete curb with a gas-powered saw, dry, for twenty minutes can put a worker well above the permissible exposure limit for respirable crystalline silica. Do the same cut with water flowing at the blade and the dust cloud mostly disappears. The federal construction silica standard, 29 CFR 1926.1153, is built around that difference.

The standard sets a permissible exposure limit of 50 micrograms per cubic meter as an 8-hour time-weighted average, with an action level of 25. It applies to all occupational exposures to respirable crystalline silica in construction work, except where exposure will remain below the action level under any foreseeable conditions. Most saw cutting, grinding, drilling, chipping and crushing of concrete, masonry, stone and tile is covered.

Two ways to comply

Paragraph (c) gives employers a choice. For each task listed in Table 1, an employer that fully and properly implements the engineering controls, work practices and respiratory protection specified for that task is not required to perform exposure assessments or demonstrate compliance with the PEL for that task. Paragraph (d) is the alternative: assess exposure by air monitoring or objective data, and keep employees at or below the PEL with whatever combination of controls works.

For a contractor without an industrial hygienist on staff, Table 1 is almost always the better path. It converts a measurement problem into an equipment and supervision problem.

What “fully and properly” means

Table 1 entries are specific. A handheld power saw cutting masonry, for example, must use a saw equipped with an integrated water delivery system that continuously feeds water to the blade, operated and maintained to minimize dust emissions. The table then specifies respiratory protection by shift duration and location. Outdoors, for four hours or less per shift, that task requires no respirator; for more than four hours, it requires an assigned protection factor of 10. Indoors or in an enclosed area the requirement is a respirator with APF 10 regardless of duration.

The “operated and maintained to minimize dust emissions” language is where many contractors lose the Table 1 safe harbor. A water feed that is clogged, a hose disconnected because the operator did not like the slurry, a vacuum with a full bag or a missing shroud, a dust collector without the filter the table calls for: each of those means the employer is no longer following Table 1. At that point the employer is required to have performed an exposure assessment under paragraph (d), and almost no one has.

Duration matters too. The four-hour threshold refers to the total time the employee performs any Table 1 task during the shift. An operator who saws for three hours and then grinds for two has done more than four hours of Table 1 work, and the respirator column for more than four hours applies to both tasks.

The written exposure control plan

Paragraph (g) requires a written exposure control plan for every covered employer, whether it uses Table 1 or not. The plan must describe the tasks that involve silica exposure, the engineering controls, work practices and respiratory protection used for each task, the housekeeping measures, and the procedures used to restrict access to work areas to minimize the number of employees exposed, including employees of other trades. The plan must be reviewed at least annually and made available to employees and their representatives.

The employer must also designate a competent person to make frequent and regular inspections of job sites, materials and equipment to implement the plan. On a busy commercial project, this is the foreman who checks that the water is flowing before the saw starts, not a safety director who visits monthly.

Housekeeping

Paragraph (f) prohibits dry sweeping or dry brushing where it could contribute to silica exposure, unless wet sweeping, HEPA-filtered vacuuming or other methods that minimize exposure are not feasible. It also prohibits using compressed air to clean clothing or surfaces where that could contribute to exposure, unless the compressed air is used together with a ventilation system that effectively captures the dust cloud. Blowing off a cutting station or clothing with an air hose at the end of the day is a citation.

Respirators and medical surveillance

Where the standard requires respirators, the employer must run a respiratory protection program meeting 29 CFR 1910.134: medical evaluation, fit testing, training and maintenance.

Paragraph (h) requires medical surveillance for each employee who will be required to wear a respirator under the silica standard for 30 or more days per year. The initial examination must occur within 30 days of initial assignment unless the employee had a qualifying exam within the last three years, and periodic exams are required at least every three years. The exam includes a chest X-ray read by a NIOSH-certified B Reader, a pulmonary function test, and testing for latent tuberculosis infection at the initial exam. The physician’s written opinion to the employer is limited to the date of the exam, a statement that it met the standard, and any limitations on respirator use; other findings go to the employee unless the employee authorizes disclosure.

Tracking the 30-day threshold requires knowing which employees wore respirators on which days. A contractor that cannot produce that tracking will have trouble showing who did and did not need an exam.

Training and records

Employees must be trained on the health hazards of silica, the specific tasks in their workplace that could expose them, the measures the employer has put in place, the contents of the standard, the identity of the competent person, and the purpose of medical surveillance. Exposure and medical surveillance records are kept under 29 CFR 1910.1020, which generally means thirty years for exposure records and the duration of employment plus thirty years for medical records.

California and the other State Plan states

California regulates construction silica under 8 CCR §1532.3, which follows the federal structure including the Table 1 approach, and general industry silica, including engineered stone fabrication, under §5204. Other State Plan states have adopted the federal standard or one at least as effective. Contractors working across state lines should confirm the state version for each project.

Frequently asked questions

If we follow Table 1, do we ever need air sampling?

Not for the tasks you fully and properly perform under Table 1. You need an exposure assessment for silica tasks not listed in Table 1 and whenever you deviate from the specified controls.

Does Table 1 cover demolition with an excavator?

Table 1 includes heavy equipment and utility vehicles used to abrade or fracture silica-containing materials, and used for grading and excavating, with specified controls such as water sprays and enclosed cabs. Each entry has its own conditions, so read the exact row for the equipment and task.

Who can be the competent person?

Someone capable of identifying existing and foreseeable silica hazards who has the authority to take prompt corrective measures. That person needs the authority to stop work.

How McNeil Safety Consulting helps

McNeil Safety Consulting writes silica exposure control plans built around a contractor’s actual equipment and Table 1 tasks, trains competent persons and crews, and audits jobsites for full and proper implementation. Michael Karl McNeil, REP, RIH, EPP, QSD, also defends silica citations under federal OSHA and Cal/OSHA. See industrial hygiene services and safety plan writing, or call (626) 546-9384 to request a consultation.

Need help with a Cal/OSHA matter?

McNeil Safety Consulting provides Cal/OSHA citation defense, industrial hygiene, safety plan writing, and expert witness services throughout California. Call (626) 546-9384 or request a consultation.