A Phase I Environmental Site Assessment ends with a list of recognized environmental conditions, and that is where a lot of buyers, lenders, and sellers freeze. The Phase I consultant has said there may be contamination; nobody has said whether there is. The Phase II is the investigation that answers the question with soil, soil vapor, and groundwater data, and how it is scoped determines whether the answer is useful, defensible, and affordable. This article is for the California property buyer, lender, or attorney trying to decide whether to order a Phase II, what it should cover, and what the results will mean for the deal.
What a Phase II Is and What It Is Not
The industry standard is ASTM E1903, Standard Practice for Environmental Site Assessments: Phase II Environmental Site Assessment Process. Where the Phase I under ASTM E1527 is a records-and-observation exercise that identifies recognized environmental conditions, or RECs, the Phase II is a physical sampling program designed to confirm or rule out the presence of hazardous substances or petroleum products the Phase I flagged. It is not a cleanup, it is not a full site characterization, and it is not a risk assessment, although it can lead to any of those.
The distinction matters because a Phase II is scoped around specific questions. Each REC becomes a hypothesis: the former dry cleaner in the corner suite may have released tetrachloroethylene to the subsurface; the hydraulic lifts in the old auto shop may have leaked oil; the fill placed on the parcel in the 1960s may contain lead or asbestos. The sampling plan is built to test those hypotheses and nothing else. A Phase II that samples “everywhere” without a hypothesis is expensive and usually still misses the one location that matters.
When Phase I Findings Call for Sampling
Not every REC needs a Phase II. The decision turns on the type of REC, the transaction, and the party’s tolerance for uncertainty. In my experience, these are the findings that most often justify moving to sampling in California:
- Historical dry cleaning, plating, machining, or other solvent use on or adjacent to the property. Chlorinated solvents migrate in groundwater and produce vapor intrusion problems, and California regulators treat them seriously.
- Current or former underground storage tanks, including tanks the regulatory file says were “closed” without confirmation sampling.
- Automotive repair, fueling, or fleet maintenance history, particularly with floor drains, clarifiers, or hydraulic lifts.
- Agricultural history with a likelihood of persistent pesticides or arsenic in shallow soil, which is common on former orchard and row-crop land now being developed for housing.
- Imported fill of unknown origin, or a parcel adjacent to a known contaminated site with a groundwater plume that may have migrated onto it.
- A lender, insurer, or regulatory agency that has said it will not proceed without data.
A REC based on a neighboring gas station three doors down and up-gradient is a judgment call. A REC based on a dry cleaner that operated in the building for 30 years is not.
How the Scope Is Set
ASTM E1903 puts the user’s objectives at the center of scoping, and this is the step buyers most often skip. Before the consultant drills anything, the parties need to agree on what the data are for. Is the goal to satisfy a lender, to negotiate a price reduction, to decide whether to walk away, to support a future regulatory closure, or to establish baseline conditions to protect a tenant? Each purpose leads to a different sampling design.
From there, scoping comes down to five decisions:
- Which media. Soil answers questions about direct contact and disposal costs. Groundwater answers questions about migration and long-term liability. Soil vapor answers the question California regulators ask most about redevelopment: whether volatile chemicals could intrude into the buildings above. On solvent sites, soil vapor is often the first and most informative medium, not the last.
- Where. Sample locations are placed to test the REC hypotheses: at the former tank, at the clarifier, downgradient of the neighbor. Random grids are rarely the right answer on a first pass.
- How deep. Depth is driven by the release mechanism and the site geology, and the consultant should be able to explain why each boring stops where it does.
- Which analytes. The laboratory list should match the suspected release. Analyzing every sample for everything wastes money and generates low-level detections that then have to be explained.
- Which screening levels. In California, results are usually compared against DTSC’s human health screening levels, published by the Human and Ecological Risk Office, and against the San Francisco Bay Regional Water Quality Control Board’s Environmental Screening Levels, which are used well beyond the Bay Area. Which set applies, and for which land use, should be stated in the work plan before sampling, not chosen after the results come in.
A written work plan covering those five points, reviewed by the buyer’s attorney before mobilization, is the single best protection against a Phase II that answers the wrong question.
Access, Permits, and the Worker Safety Piece
Two practical items get overlooked. First, drilling on someone else’s property requires an access agreement, and it should address who owns the data, whether the seller sees the results, and who is responsible if the consultant hits a utility. Second, borings and monitoring wells in most California counties require a permit from the local environmental health or water agency, and the permit timeline can be longer than the drilling itself.
The safety side is one I take personally. A Phase II crew is working around a drill rig, potentially in contaminated soil, sometimes on an active commercial site. If the work is being done under an agency directive or at a site an agency recognizes as an uncontrolled hazardous waste site, Section 5192 applies and the crew needs HAZWOPER training and a site-specific plan. Even where it does not, the drilling contractor and the consultant each need an IIPP that addresses the actual hazards, and the property owner should ask to see them.
What the Results Mean for the Transaction
Phase II results fall into three buckets, and each one has a different transactional meaning.
- No detections, or detections below the applicable screening levels for the intended use. The REC is generally resolved for that medium, the lender is usually satisfied, and the buyer has a documented baseline. It does not mean the site is clean everywhere; it means the hypotheses tested were not confirmed.
- Detections above screening levels, but limited in extent. This is the most common outcome and the one that requires the most judgment. The screening levels are conservative by design. Exceeding one triggers further evaluation, not automatically a cleanup. The next steps are usually delineation to define the extent, a site-specific risk evaluation, or a cost estimate for removal that becomes a price negotiation. Vapor intrusion exceedances on a residential redevelopment often lead to engineered mitigation in the building design, which is a solvable cost rather than a deal killer.
- Significant contamination, groundwater impacts, or an off-site source. Here the questions become regulatory. A release that affects groundwater generally has to be reported, the site may enter an oversight program with DTSC or the Regional Water Board, and the buyer needs to understand the liability position before closing. Prospective purchaser agreements and other liability tools exist, but they take time and legal work.
Two reminders. Data have consequences: once a release is known, reporting obligations may attach regardless of whether the deal closes, and the parties should discuss that with counsel before the samples are collected. And a Phase II report is a snapshot of the locations tested; it should state its limitations plainly rather than implying a site-wide clean bill of health.
What to Do Now
- List every REC from the Phase I and write, in one sentence each, the hypothesis a Phase II would test.
- Decide with counsel what the data are for and who will receive the report.
- Get a written work plan that states media, locations, depths, analytes, and the screening levels to be used.
- Confirm the access agreement addresses data ownership and reporting obligations.
- Ask the consultant and driller for their safety plans, and confirm HAZWOPER coverage if Section 5192 applies.
- Build the permit timeline into the due diligence period before you sign it.
- Plan for the middle outcome: know what delineation or mitigation would cost before the results arrive.
If your Phase I came back with RECs and you need a Phase II scoped to answer the questions your deal actually depends on, McNeil Safety Consulting can help. Learn more about our environmental assessment services or call (626) 546-9384.