Air Compressor Tanks and the Cal/OSHA Permit to Operate: Title 8, Sections 461 and 462

By Michael Karl McNeil, REP, RIH, EPP, QSD

The air compressor in the corner of the shop sits on a pressure vessel, and unless that vessel is very small, California requires a Cal/OSHA permit to operate it. Where I see employers fall short is a tank with no permit at all, or a posted permit that belongs to a tank that was replaced. This article covers which air tanks need a permit under Title 8, Section 461 of the Unfired Pressure Vessel Safety Orders, the size and pressure exemptions, the inspection intervals in Section 462, who is allowed to inspect, and where the permit has to be posted.

What Counts as an Air Tank

Section 453 defines an air tank as a pressure vessel used for the storage or accumulation of air under pressure. Under Section 450(a), the Unfired Pressure Vessel Safety Orders apply to places of employment in California and set minimum standards for, among other things, the installation, use, repair and alteration of air tanks and the inspection of and issuance of permits to operate for them.

Section 451 lists vessels that are not subject to the orders. Two entries matter for compressed air:

  • Section 451(b): pressure vessels subject to an internal or external pressure of not more than 15 psig (except those listed in Section 450(a)(5), which addresses natural gas motor fuel vessels), and vessels having an inside diameter not exceeding 6 inches with no limitation on pressure.
  • Section 451(c): air brake tanks subject to the jurisdiction and inspection of the Public Utilities Commission, the Department of Transportation or the Department of the California Highway Patrol, except as provided in Article 7 of the orders.

The Basic Rule in Section 461

Section 461(a) states that no air tank shall be operated unless a permit to operate has been issued. The sentence has two exceptions: the time during which a request for a permit remains unacted upon, and the small tanks described in subsection (f).

Subsection (b) makes operating an air tank that requires a permit without one a misdemeanor for every person owning or having the custody, management or operation of the tank, with each day of operation a separate offense. Subsection (g) reaches rental equipment: an air tank requiring a permit may not be rented or offered for rent for use in a place of employment unless the permit has been issued by or in behalf of the Division.

Tanks That Need No Permit and Tanks That Get an Indefinite Permit

No Permit: Section 461(f)

Air tanks having a volume of 1 1/2 cubic feet or less, with safety valves set to open at not more than 150 psi, do not require permits to operate. By my conversion that is a tank of roughly 11 gallons. The subsection adds that these tanks shall comply with all other provisions of the orders, including construction. Self-contained breathing apparatus tanks of 1 cubic foot or less that are constructed, inspected and maintained in accordance with DOT regulations also do not require permits.

Indefinite Permit: Section 461(h)

Air tanks subject to a maximum allowable working pressure not exceeding 150 psi, as shown by the required code marking, and having a volume of 25 cubic feet or less (roughly 187 gallons by my conversion) shall be inspected when placed into service. An indefinite permit is issued, provided the tank was constructed, inspected and stamped in compliance with the ASME Code, or the Division accepts its design, material and construction as equivalent, and the tank complies with the applicable provisions of the orders. A new inspection and permit are required whenever there is a change of ownership and permanent location, or an alteration or change in the tank that affects its safety.

A 60-gallon or 80-gallon shop tank is under the 25 cubic foot limit. It still needs a permit. Whether it qualifies for the indefinite kind turns on the maximum allowable working pressure on its code marking, and a tank marked above 150 psi does not fit subsection (h).

Periodic Permit: Section 461(d)

For every other tank, the permit expires not more than 5 years from the date of inspection, or not more than three years for portable air tanks. It also expires upon alteration of, or damage to, the air tank or installation, or upon change of ownership and location, whichever occurs first. The note to subsection (d) says the permit for a portable tank does not expire upon change of ownership and location. Section 453 defines a portable air tank as an air tank mounted with an air compressor on a towed vehicle. As I read it, a wheeled shop compressor moved by hand does not fit that definition. Under subsection (e), a temporary permit may be issued for not more than 30 days to allow a reasonable time for required changes.

Inspection Intervals and Who Inspects

Under Section 462(a), all air tanks requiring a permit shall be inspected internally and externally by a qualified inspector at least once every 3 years for portable tanks and once every 5 years for all other tanks. That subsection does not apply to tanks that meet the requirements for an indefinite permit under Section 461(h). The internal inspection of a tank less than 2 years old may be waived at the discretion of the inspector, provided the other requirements of Section 462(c) are met.

Section 453 defines a qualified inspector as either a certified inspector or a qualified safety engineer. Both hold a valid certificate of competency issued by the Division. Section 463 requires inspectors to be certified in accordance with Section 779 of the Boiler and Fired Pressure Vessel Safety Orders. Section 462 refers to Division safety engineers, to qualified inspectors employed by insurance companies, and to qualified inspectors employed by others. A safety audit by a consultant does not substitute for that inspection.

Section 462(b) requires the owner or user to prepare the tank for inspection when requested by the Division or a qualified inspector, including removing inspection plugs or plates the inspector deems necessary. If the date set is not convenient, the owner or user must immediately ask the Division for a postponement and give good cause, and the postponement cannot exceed 30 days. Under Section 462(d), permits are issued only if tanks and systems comply in all respects with the orders and all inspection fees are paid.

Posting the Permit and Installation Requirements

Section 461(c) requires the permit to be posted under glass in a conspicuous place on or near the air tank, or in a weatherproof container secured to the unit, and to be available at all times to any qualified inspector. A permit in the office file cabinet does not meet that subsection.

These installation requirements are the ones I find out of order most often:

  • Section 462(a)(2): drains, handholes, inspection plugs and manholes easily accessible, with clearance for a complete external inspection. An air tank shall not be buried underground or located in an inaccessible place.
  • Section 465(a) and (b): one or more safety valves, set to open at not more than the allowable working pressure of the tank and tested frequently and at regular intervals.
  • Section 465(d): a pressure gage graduated to approximately double the operating pressure, and in no case less than 1.2 times the safety valve setting.
  • Section 465(e): a manually operated, valved drain at the lowest point where water can collect. An automatic drain complies only if it also has a manually operated by-pass.
  • Section 462(m): Schedule 80 metallic pipe from the tank to the first shut-off valve. Plastic air piping, other than pipe or tubing under 3/8-inch diameter, is allowed only under the conditions in subsection (m)(3) or (m)(4), both of which cap pressure at 150 psi.

Section 462(l)(4) requires the employer to notify the Division and the inspection agency before further use in the event of cracking or leaking of the air tank. Section 466(a) prohibits any alteration or repair affecting the safety of an air tank without the authorization of a qualified inspector.

What to Do This Week

  • Inventory every air tank on site and record its volume, the maximum allowable working pressure on the code marking, the safety valve setting and the State serial number stamped on it under Section 462(g).
  • Sort each tank into Section 461(f), 461(h) or 461(d) using those numbers.
  • Find the permit for every tank that needs one, check its date against the three-year or 5-year limit, and post it at the tank as Section 461(c) describes.
  • Flag any tank bought used, moved to a new location, altered or damaged since its last inspection (Section 461(d) and (h)).
  • Ask your rental supplier for the permit on any rented compressor (Section 461(g)).
  • Check the safety valve, gage, manual drain and the first run of piping against Sections 465 and 462(m).

To have your compressed air systems and the rest of your shop equipment reviewed against Title 8, see my safety audit service or call (626) 546-9384.